Ohm’s law: work out voltage, current, resistance and power
Enter any two values from voltage U, current I, resistance R and power P – the calculator gives the other two, with the formula and calculation steps. Design and installation belong in the hands of a qualified electrician.
In short Example: U = 230 V and P = 2,300 W give I = 10 A and R = 23 Ω. Rules: U = R × I and P = U × I; from two known quantities the other two follow.
An example step by step
At U = 230 V and P = 2,300 W (for example a fan heater), I = 10 A flows and the resistance is R = 23 Ω (I = P ÷ U = 2,300 W ÷ 230 V = 10 A, R = U² ÷ P = (230 V)² ÷ 2,300 W = 23 Ω).
- 1GivenU = 230 V, P = 2,300 W
- 2Current II = P ÷ U = 2,300 W ÷ 230 V = 10 A
- 3Resistance RR = U² ÷ P = (230 V)² ÷ 2,300 W = 23 Ω
- Result: Current I: 10 A
How we calculate
Ohm’s law links voltage U (volts), current I (amperes) and resistance R (ohms): U = R × I. Together with the power P (watts), P = U × I applies. From these two equations all four quantities can be converted into one another as soon as two are known.
U = R × I · I = U ÷ R · R = U ÷ I
P = U × I · P = I² × R · P = U² ÷ R
The calculator chooses the suitable rearrangement depending on the input. If, for example, I and P are known, U = P ÷ I and R = P ÷ I² follow. If R and P are known, I = √(P ÷ R) and U = √(P × R). If more than two values are entered, the first two in the order U, I, R, P count.
The formulas apply to direct current and to resistive loads on alternating current, such as a heating element, cooker or incandescent lamp. For motors, power supplies and coils, a reactive component and the power factor cos φ come into play; the real power then differs.
All twelve formulas with numbers
Example: U = 230 V, I = 10 A, R = 23 Ω, P = 2,300 W. Each quantity can be calculated from two others.
| To find | From | Formula | Example |
|---|---|---|---|
| Voltage U | R and I | U = R × I | 23 Ω × 10 A = 230 V |
| Voltage U | P and I | U = P ÷ I | 2,300 W ÷ 10 A = 230 V |
| Voltage U | P and R | U = √(P × R) | √(2,300 W × 23 Ω) = 230 V |
| Current I | U and R | I = U ÷ R | 230 V ÷ 23 Ω = 10 A |
| Current I | P and U | I = P ÷ U | 2,300 W ÷ 230 V = 10 A |
| Current I | P and R | I = √(P ÷ R) | √(2,300 W ÷ 23 Ω) = 10 A |
| Resistance R | U and I | R = U ÷ I | 230 V ÷ 10 A = 23 Ω |
| Resistance R | U and P | R = U² ÷ P | (230 V)² ÷ 2,300 W = 23 Ω |
| Resistance R | P and I | R = P ÷ I² | 2,300 W ÷ (10 A)² = 23 Ω |
| Power P | U and I | P = U × I | 230 V × 10 A = 2,300 W |
| Power P | I and R | P = I² × R | (10 A)² × 23 Ω = 2,300 W |
| Power P | U and R | P = U² ÷ R | (230 V)² ÷ 23 Ω = 2,300 W |
Appliances on 230 V: current and resistance
Current and resistance of typical resistive loads at 230 V, calculated with I = P ÷ U and R = U² ÷ P.
| Appliance | Power P | Current I | Resistance R |
|---|---|---|---|
| Kettle | 2,000 W | 8.70 A | 26.45 Ω |
| Hair dryer | 1,800 W | 7.83 A | 29.39 Ω |
| Toaster | 800 W | 3.48 A | 66.13 Ω |
| Incandescent lamp | 60 W | 0.26 A | 881.67 Ω |
| LED lamp | 10 W | 0.04 A | 5,290 Ω |
Cable calculator app
Checks voltage drop, cable size and power – with a traffic light for the limit value. In the browser you check one cable – in the app whole circuits and cable lists, with a PDF for your customers.
- Projects & rooms
- PDF with logo
- Your own defaults
- Offline, no account
Common questions
What does Ohm’s law say?
Voltage is resistance times current: U = R × I. 23 Ω and 10 A give 230 V. Rearranged, this gives I = U ÷ R and R = U ÷ I.
How do I calculate power?
With P = U × I in watts. At 230 V and 10 A that is 2,300 W. With Ohm’s law, P = I² × R and P = U² ÷ R also apply.
How do I convert watts to amps?
With I = P ÷ U. A 2,000 W kettle draws around 8.70 A at 230 V. For three-phase (3~ 400 V) the factor √3 is added; the power calculation in the electrical calculator covers that.
Which two values do I need?
Any two of the four quantities U, I, R and P. The calculator gives the other two. If more than two are entered, the first two in the order U, I, R, P count.
Does this also apply to alternating current?
For resistive loads such as a heating element, cooker or incandescent lamp, yes. With motors, power supplies and coils a reactive component and cos φ come into play, and the real power then differs. For cables, use the voltage drop calculator.
Does the calculator replace an inspection by a qualified electrician?
No. The results are guide values. Current-carrying capacity and protective device must be checked separately; design and installation are the job of a qualified electrician.